Monday, September 19, 2016

Foxeer TM25 switcher VTx test power

I made power test of Foxeer switcher, sorry because is an older one (at the moment is new version example)

I dont wire main features because there is a lot information in internet. Main goals is test power outputs on all channels.

To change power you need to hold button when blinks you change power output .

1. 25mW
2. 200mW
3. 600mW

then you switch band
1.
2.
3.
4.
5.

and the least channel
1 to 8ch


Table witch Frequency
FRCH CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8
A(1.) 5865 5845 5825 5805 5785 5765 5745 5725
B(2.) 5733 5752 5771 5790 5809 5828 5847 5866
E(3.) 5705 5685 5665 5645 5885 5905 5925 5945
F(4.) 5740 5760 5780 5800 5820 5840 5860 5880
R(5.) 5658 5695 5732 5769 5806 5843 5880 5917


Test bench - Agilent power metter with power sensor



For 25mW result

Band/CH
1
2
3
4
5
6
7
8
1.
150
155
159
162
166
170
176
180
2.
177
172
166
159
153
146
139
138
3.
184
188
195
201
125
116
110
99
4.
172
107
105
100
69
142
134
126
5.
121
118
112
109
105
95
86
76


For 200mW result 
Band/CH
1
2
3
4
5
6
7
8
1.
85
87
85
90
95
98
97
100
2.
108
102
99
97
94
91
89
86
3.
138
139
143
150
105
95
88
81
4.
155
150
150
146
106
105
97
90
5.
146
152
141
138
131
140
138
113

For 600mW result 
Band/CH
1
2
3
4
5
6
7
8
1.
262
264
267
269
270
272
274
276
2.
272
268
266
275
274
271
268
262
3.
279
283
286
292
259
255
248
240
4.
271
268
265
264
266
262
258
254
5.
290
281
274
270
269
262
255
245




Summary:

- as we can see there is a very different power as need to be
- other thing is that at the same channel at the same power ( i mean for example raceband 7 and F8 different power)
 - one as i can write that it works and you will have visual but not as you prefer, too much on 25mW lower at 200mW and even not 300mW on 600mW.

Maybe will have new version so can be compare :) in next will be immersion F because i had one and shipping TBS Pro Race.

No comments:

Post a Comment